Set
outputting relay contacts to achieve multiple functions.
Contact between FA and FC is normally open;
contact between FB and FC is normally close.
Set function code Cd674 to select functions for outputting relay contacts:
Cd674=
0: Output at alarm status
1: In operation 1
2: Low voltage
3: End of simple scheduled operation
4: In operation 2
5: Frequency matching (1st speed frequency)
6: Frequency matching (1st to 8th speed frequencies)
7: Frequency approach
8: Overload alarm level setting (Cd048 value. Output only in constant
operation.)
9: Electronthermal level signal (Electronthermal 80%)
10: Fin heat prediction signal
11: Auxiliary pump driving signal (Option)
12: Regular pump switching signal (Option)
13: Excitation and DC braking
14: Lower frequency limit matching
15: Upper frequency limit matching
16: Servo ON-signal (Option)
17: Zero servo completion signal (Option)
18: FR signal
19: RR signal
20:2DF signal
21:3DF signal
22:AD2 signal
23:AD3 signal
24: JOG signal
25: MBS signal
26: ES signal
27: RST signal
28: Switching standby signal (Option)
29: Positioning completion signal (Option)
30: Discharge resistor ON-signal
31: Reserved
32: Reserved
33: Reserved
34: Overload alarm signal (Cd048 value. Output when in operation.)