Function code data copy function

This function transfers function code data from the inverter to the operation panel or to another inverter.
Cd084=1: Transfers the current function code data to the operation panel.
Cd084=2: Transfers the memory contents from the operation panel to the inverter.
Note: The copy function is controlled using the software version numbers, and may not work if the software versions are not compatible. In addition, there may be cases where alarms and other functions do not behave as expected when settings are copied from one inverter that has additional functions to another inverter that does not have these functions due to a difference in software. Be sure to confirm that all required functions are available before copying settings to an inverter. We recommend that you install a software upgrade if the software versions of the inverters are significantly different. For details of upgrades, please contact the retailer.