VVVF Inverter
SAMCO-vm05
Functions
Description
Software upgrade function
A function to upgrade the inverter's software
Standard configuration of communication function
RS232C/RS485 standard configuration (no options needed)
 
Anti ¨Cbreakdown function
Operation time for anti-breakdown can be set
Output frequency range spreading function
Output frequency: 0.05Hz-600Hz
 
Multifunctional output and input terminals
Users can set the output and input terminals freely.
Analog output function
Two 0-10V analog signal outputs
Multifunctional relay output
Add same functions as in multifunctional output terminals to alarm relay.
Analog frequency input command
0-10V and 4-20mA analog signal inputs can be converted to each other.
Power supply for users
Provide 24V 150mA power supply
 
User's initialization data
The user is allowed to set initialization data.
Changed code display function
This function displays data values in current code data that are different from the factory presets and user's initialization data.
Function code data copy function
Function code data can be copied to multiple inverters with a operation panel.
Shortest operation time compensation function
The operation is enabled in the shortest set time even if the operation times specified by different codes are not equal.
Password function
The user is allowed to set the password enabling continuous use of the machine.
Missing phase detection function
Missing input or output phase can be detected by specifying different function codes.
V.f separate function
V.f comparison and complete separation
V/f pattern function
The user is allowed to set V/f curve by use of multiple voltage and frequency setting points.
Cooling FAN lock inspection function
Lock of cooling fan caused by fault, external reasons can be inspected.
Constant pressure water supply system control
Fixed mode, cycling mode, scheduled switch, pump switch by external terminals
Rolling machine control function
Can be used to control drawbench, rolling machine, twist machine, etc.
Position control The optional board SB-PG can be used to control positioning.
 
Vm05 new functions
Specifications

400V SHF Series(1.5KW~15KW)
400V SHF Series(18.5KW~55KW)
400V SPF Series(2.2KW~18.5KW)
400V SPF Series(22KW~75KW)

<<<(Click to open)
<<<(Click to open)
<<<(Click to open)
<<<(Click to open)

External Dimensions
SHF-1.5K~SPF-4.0K

SHF-2.2K~SPF-5.5K
Type
D
SHF-1.5K
SHF-2.2K
SHF-4.0K
SPF-2.2K
SPF-4.0K
SPF-5.5K
170

Unit:mm
SHF-5.5K~SHF-15K
SPF-7.5K~SPF-18.5K
Type
H
H1
W
W1
D
SHF-5.5K
300
280
200
180
205
SHF-7.5K
SHF-11K
SPF-7.5K
SPF-11K
SPF-15K
SHF-15K
360
340
240
220
205
SPF-18.5K

Unit:mm
SHF-18.5K~SHF-55K
SPF-22K~SPF-75K
Type
H
H1
W
W1
D
d
SHF-18.5K
390
370
270
248
215
7
SHF-22K
SPF-22K
240
SPF-30K
SHF-30K
440
420
340
318
240
7
SHF-37K
SPF-37K
SPF-45K
SHF-45K
550
530
340
318
260
7
SHF-55K
SPF-55K
SPF-75K

Unit:mm
Installation method of operation panel
Copyright © 2004 Sanken L.D. Electric (Jiang Yin) Co., LTD. All rights reserved.